BruxZir® Esthetic Implant Prosthesis
BruxZir Esthetic Implant Prosthesis

BruxZir® Esthetic Implant Prosthesis

$3,837*

*Price does not include shipping or applicable taxes and may vary when original equipment manufacturer (OEM) components are requested or required. No additional charge for multi-unit abutments. Copy mill service is also available.

Please note pricing is only available to dental professionals.

The BruxZir® Esthetic Implant Prosthesis offers a high-strength option for edentulous implant patients with high esthetic expectations — without the risk of fracturing the veneering material used in most premium full-arch zirconia restorations.

    • Constructed from 100% monolithic zirconia
    • Unprecedented combination of premium esthetics and strength
    • Optimized translucency and exceptional gingival anatomy
    • Includes provisional try-in implant prosthesis

    A Better Smile, A Better Life

    With the introduction of the BruxZir Esthetic Implant Prosthesis, clinicians now have a long-lasting solution whether your priority is strength or beauty. While the original BruxZir Implant Prosthesis is recommended for patients who have a strong bite, grind, or have damaged previous restorations, the BruxZir Esthetic Implant Prosthesis is ideal for patients with high esthetic expectations. In addition to avoiding the chips, stains and fractures known to compromise acrylic hybrid dentures and dental porcelain, BruxZir Esthetic offers lifelike beauty that will “wow” your edentulous patients.

    A truly monolithic implant restoration, the BruxZir Esthetic Implant Prosthesis is milled from a block of 870 MPa solid zirconia. When a restoration calls for premium esthetics, the BruxZir Esthetic Implant Prosthesis is a cost-effective solution — without the risk of fracturing layered porcelain.

    The BruxZir Esthetic Implant Prosthesis includes a new and improved step-by-step protocol that streamlines the restorative process. Our five-appointment protocol, supported by instructional guides, videos and technical support staff, minimizes the likelihood of wax reset appointments and ensures a predictable outcome. A provisional try-in implant prosthesis is included to ensure that the patient and doctor are satisfied with the prosthetic design before the final restoration is milled from BruxZir Esthetic Zirconia.

    Note: The BruxZir Esthetic Implant Prosthesis is ideal for patients who desire a high-strength restoration with optimal esthetics. For maximum strength, we recommend the original BruxZir Implant Prosthesis.

    Also available for partial-arch indications: The BruxZir Esthetic Partial-Arch Implant Prosthesis is a more durable replacement for removable partial dentures.

    BruxZir® Esthetic Implant Prosthesis

    Validations

    Monthly Prescriptions: BruxZir Implant Prosthesis vs. Screw-Retained Hybrid Denture

    Since the product’s release in 2013, monthly prescriptions for the BruxZir Implant Prosthesis have steadily outpaced screw-retained hybrid dentures as clinicians have sought out a more durable implant solution for fully edentulous patients.

    BruxZir Full-Arch vs. Screw-Retained Hybrid Denture

    Clinical Studies

    When a full-arch implant patient prioritizes esthetics above all else, it’s wonderful to have a monolithic zirconia restoration that meets that need but won’t break down. And for my patients with parafunctional habits, I can still count on the maximum strength of the original BruxZir Implant Prosthesis.

    Paresh B. Patel, DDS image
    Paresh B. Patel, DDS

    Specifications

    Indications

    The BruxZir Esthetic Implant Prosthesis is indicated as a fixed restorative solution for the fully edentulous arch.


    Material Composition

    100% monolithic zirconia with titanium connections


    Strength Characteristics

    ≥870 MPa of flexural strength

    In-Lab Working Times

    Full Service:

    • Implant verification jig, custom tray and wax rim: 9 days
    • Wax setup: 5 days
    • Provisional try-in implant prosthesis: 6 days
    • Final BruxZir Implant Prosthesis: 8 days

    Available Shades

    • Tooth shades: A1, A2, A3, A3.5, A4, B1, B2, B3, B4, C1, C2, C3, C4, D2, D3, D4
    • Gingival shades: G0 (light), G1 (Standard), G3 (Med), G4 (Dk)

    Pricing

    BruxZir Esthetic Implant Prosthesis

    Includes up to six multi-unit abutments and two full-arch provisional try-in prostheses. Any additional provisional try-in prostheses incur a fee of $330 each. Additional multiunit abutments incur a fee of $116 each.

    $3,837.001
    Copy mill from approved setup for provisional and full-arch zirconia prosthesis
    $2,142.00
    Copy mill from approved setup for full-arch zirconia prosthesis
    $1,914.00
    Duplicate Provisional Try-In Implant Prosthesis(copy mill cases)
    $460.00
    Add titanium bar(zirconia prosthesis over hybrid bar)
    + $813.00
    BruxZir Esthetic Partial-Arch Implant Prosthesis

    5–7 units, includes Partial-Arch Provisional Try-In Implant Prosthesis

    $2,026.00
    1

    Half of payment is due after first appointment; half is due at final delivery.

    Note: Prices may vary when original equipment manufacturer (OEM) components are requested or required for the chosen implant system.

    Pricing is subject to change and does not include shipping or applicable taxes.

    View full price list


    Service Options

     

    • Full Service: Includes final prosthesis, provisional try-in implant prosthesis, labor, model work, analogs, setups, wax rims, try-ins, and custom trays with implant verification jig. No additional charge for multi-unit abutments.
    • Copy Mill With Provisional: Copy-mill from approved setup for provisional and full-arch zirconia prosthesis
    • Copy Mill Without Provisional: Copy-mill from approved setup for full-arch zirconia prosthesis

    Implant System Compatibility

    Flat-rate price available for BIOMET 3i™ Certain®; CAMLOG® SCREW-LINE; DENTSPLY Implants ANKYLOS® C/X and ASTRA TECH Implant System®; Hahn™ Tapered Implant System; HIOSSEN® HG System; Inclusive® Tapered Implant System; MegaGen AnyRidge® Implant System; Nobel Biocare Brånemark System® RP, NobelActive® and NobelReplace®; Straumann® Bone Level and Tissue Level; and Zimmer Dental Screw-Vent®. Prices may vary for other implant systems due to the need for original equipment manufacturer (OEM) components.

    Inclusive is a registered trademark of Prismatik Dentalcraft, Inc. Hahn Tapered Implant is a trademark of Prismatik Dentalcraft, Inc. All other trademarks are property of their respective owners.


    Policies & Warranty

    NO-FAULT REMAKE POLICY: Glidewell is pleased to process all remakes or adjustments at no additional charge if requested within the warranty period and accompanied by the return of the original appliance.

    NOTE: For copy-mill service, remakes or adjustments are not permitted unless due to manufacturer workmanship issues, such as fracture, incorrect shade and debonding. Design changes are not covered under warranty for restorations fabricated via the copy-mill service.

    LIMITED WARRANTY/LIMITATION OF LIABILITY. Glidewell (“the lab”) warrants that all dental devices (a “device”) are made according to your specification and approval in the belief that the device will be useful and MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Subject to the return of a device that is placed and then fails, the lab will repair or replace the device without charge for the cost of materials and workmanship or refund the original price paid, at the lab’s option, for the life of the patient originally receiving the restoration from the date of placement for the BruxZir Implant Prosthesis and 60 days for the provisional implant prosthesis.*

    *Warranty is provided to the prescribing dentist and is nontransferable. For complete warranty details, go to glidewell.com/policies-and-warranties.

    Resources

    Clinical Tips

    • Tooth-colored composite or acrylic should be used to close access holes in the teeth, while pink composite or acrylic should be used to close access holes in the prosthesis base.
    • The implant verification jig provided by the lab for the final impression is crucial in helping ensure a passive fit for your restoration.
    • Gingival Shade Guides are recommended to help ensure an optimal match with the patient’s soft tissue, and are available here.

    Procedures

      Loading results...

      Additional Resources

      Literature

        Loading results...

        Media

        Categories
            Loading results...